Catalog

Description

The catalog service allows to register or modify your own sensors/components or query the characteristics of a sensor or provider.

All requests for this service will have the following format:

http://<your_api_server.com>/catalog/<provider_id>

where provider_id is optional and should be included depending on the operation.

Component types

The list of component types should be configured for each Sentilo instance, the following list could be used as a reference for any city:

Id Name Description
temperature Temperature Temperature measurement
noise Soundmeter Sound measurement
wind Anemometer Wind speed
humidity Humidity Humidity measurement
air_quality Air Quality Air Quality control
water_quality Water Quality Water Quality control
meteo Meteorology Weather Station
parking Occupation parking Parking control
luminosity Luminosity Luminosity measurement
glass_container Occupancy container level Glass occupancy container measurement
paper_container Occupancy container level Paper occupancy container measurement
plastic_container Occupancy container level Plastic occupancy container measurement
organic_container Occupancy container level Organic occupancy container measurement
refuse_container Occupancy container level Refuse occupancy container measurement
container_volum Occupancy container level Generic occupancy container measurement
soil_moisture Soil moisture Soil moisture measurement
park_meter Parking meter Parking meter control
traffic Traffic Traffic measurement
people_flow People flow Pedestrian flow measurement
flowmeter Water flow Water flow measurement
solenoid_valve Electrovalve Solenoid control
salinity Salinity Soil salinity measurement
internal_ambient_cond itions Internal Environmental Conditions Temperature, humidity and luminosity measurement
external_ambient_cond itions External environmental conditions Temperature, humidity and luminosity measurement
network_analyzer Network analyzer Electric network analyzer
gas_meter Gas meter Gas consumption meter
electricity_meter Electricity meter Electricity consumption meter
water_meter Water meter Water consumption meter
soil_sensor Soil sensor Soil mesurement of salinity, mosture, etc
generic Generic component type Default component type if not specified
plugsense Plug & Sense Plug & Sense Libelium component

Sensor types

The list of sensor types should be configured for each Sentilo instance, the following list could be used as a reference for any city:

Id Name Description
temperature Temperature Temperature measurement
noise Soundmeter Class II Sound level measuring class II.
noise_class_i Soundmeter Class I Sound level measuring class I
anemometer Anemometer Wind Speed ​measuring
humidity Humidity Humidity measuring
parking Occupation parking Occupation parking control
luminosity Luminosity Luminosity measuring
container_volum Occupancy container level Occupancy container measurement
container_overturn Container overturned Container overturned indicator
container_open Container open Container opening indicator
status Sensor status Status control
battery Battery level Battery level measurement
soil_moisture_15 Soil moisture 15 cm. Soil moisture measurement
soil_moisture_35 Soil moisture 35 cm. Soil moisture measurement
park_meter Parking meter Parking meter control
vehicle_volume Number of vehicles Measurement of number of vehicles
vehicle_occupation_av erage Average occupancy Measurement of average occupancy in vehicles
vehicle_speed Speed ​​Vehicle Vehicle speed ​​measurement
air_quality_no2 NO2 Nitrogen dioxide measurement
air_quality_pm10 PM10 Measurement of suspension particles PM10
air_quality_pm25 PM25 Measurement of supsension particles PM25
air_quality_o3 O3 Ozone measurement
air_quality_so2 SO2 Sulfur dioxide measurement
air_quality_co CO Carbon Monoxide measurement
air_quality_co2 CO2 Carbon dioxide measurement
people_flow People flow Measurement of pedestrian flow
flowmeter Water flow Water flow measurement
solenoid_valve Electrovalve Solenoid actuator
eto Evotranspiration Evotranspiration measurement
salinity Salinity Soil salinity measurement
pluviometer Pluviometer Rain measurement
rain Rain gauge Rain indicator (it’s raining/it’s not raining)
wind Wind gauge Wind indicator (>X m/s)
wind_direction_6_m Wind direction Wind direction at 6 meters
wind_direction_10_m Wind direction Wind direction at 10 meters
voltage Voltmetre Electrical voltage measurement. Units: volts (V)
current Ammeter Electrical intensity measurement. Units amps (A)
frequency Frequencymeter Electrical frequency measurement. Units: herzs (Hz)
active_power Active power Active power measurement. Units: kilowatts (kW)
reactive_power Reactive power Reactive power measurement. Units: reactive kilovoltiamperis (kvar)
cosphi Power factor Sensor that relates the active and reactive power. No units
active_energy Active electrical energy meter Measurement of accumulated active power. Units: kWh.
reactive_energy Reactive electrical energy meter Measurement of accumulated reactive power. Units: kvarh.
gas_volume Gas meter Measurement of accumulated gas consumption. Units: m3 o Nm3
water_meter Water meter Measurement of accumulated water consumption. Units: m3 o l
global_solar_irradian ce Global solar irradiance Mesurement of solar irradiance
leaf_moisture Leaf moisture Leaf wetness
oxygen Oxygen O2
vertical_level Vertical level Vertical liquid level (water)
bend Bend Bend
lpg Lpg Liquified petroleum gases (H2, CH4, ethanol & isobutane)
crack_detection Crack detection Crack detection gauge
solar_radiation Solar radiation Solar radiation
voc Voc Volatile Organic Compounds
chloride_ion Chloride ion Ion Cl-
temperature Temperature Soil/Water temperature
magnessium_ion Magnessium ion Ion Mg2+
distance Distance Distance (by metalic pressure or by pressure)
conductivity Conductivity Conductivity
liquid_leakage_line Liquid leakage line Water Leakage / Liquid Detection (Line)
crack_propagation Crack propagation Crack propagation gauge
nitrate_ion Nitrate ion Ion NO3
hall_effect Hall effect Hall effect
vibration Vibration Vibration (lamina)
copper_ion Copper ion Ion Cu2+
calcium_ion Calcium ion Ion Ca+
dendometer Dendometer Trunk, stem or fruit diameter
iodide_ion Iodide ion Ion I-
bromide_ion Bromide ion Ion Br-
sodium_ion Sodium ion Ion Na+
linear_displacement Linear displacement Linear displacement
atmospheric_pressure Atmospheric pressure Atmospheric pressure
methane Methane CH4
pressure Pressure Pressure/ Weight
ammonia Ammonia NH3
redox_potential Redox potential Oxidation Reduction Potential
proximity_indoor Proximity indoor Ultrasound (indoor)
air_pollutant Air pollutant Air pollutants-I (NH3, SH2, ethanol and toluene) and air pollutants-II (H2, CH4, CO, ethanol and isobutane)
liquid_leakage_point Liquid leakage point Water Leakage / Liquid Detection (Point)
proximity_outdoor Proximity outdoor Ultrasound (outdoor IP67)
potassium_ion Potassium ion Ion K+
o_saturation O saturation Dissolved Oxygen
presence Presence Presence (PIR)
stretch Stretch Stretch
liquid_level Liquid level Horizontal liquid level (combustibles or water)
load Load Load
fluoride_ion Fluoride ion Ion F-
ph Ph pH
solvent_vapors Solvent vapors Solvent vapors (H2, CH4, CO, ethanol and isobutane)
accelerometer Accelerometer Accelerometer